1. Main Unit of Recovery Machine |
12. Cooling Water Discharge Valve |
2. Thermal Oil Filling Port |
13. External Power Cable |
3. Thermal Oil Observation Port |
14. Electrical Box Exhaust Fan |
4. Electric Heating Tube |
15. Control Panel |
5. High-Pressure Safety Valve |
16. Vacuum Pump Exhaust Port |
6. Waste Solution Suction Valve |
17. Waste Sediment Discharge Valve (Internal) |
7. Waste Sediment Observation Port |
18. Adjustable Support Legs |
8. Solvent Level Observation Port |
19. Pressure Vacuum Gauge |
9. Solution Cooling Water Tank |
20. Solution Pressure Release Valve |
10. Recovered Solution Vacuum Tank |
21. Solution Flow Direction Tube |
11. Recovered Solution Water Level Tube |
22. Solution Discharge Valve |
1. Connect the power cable. Set the timer to 4H30 for tetrachloride-based operations and adjust the temperature control to 175°C. The parameters must be adjusted based on the data provided by the solution supplier.
2. Turn on all switches on the control panel. Wait until the pressure (19)reaches -0.06 or above. Open valve (6) and draw the waste solution into the recovery machine. Once the solvent level in (8) approaches the top of the glass, close valve (6).
3. Note: After each recovery process is completed, wait for 30 minutes before opening the side door of the frame (17). At the bottom, there is a 2-inch waste discharge port. Open the largest valve to completely drain the waste residue before starting the next recovery.
1.The whole machine is made of stainless steel, which is corrosion-resistant and beautiful. It is equipped with a special explosion-proof temperature control button.
2.The seal of this machine adopts a mold-customized overall seal, which has good sealing performance and long service life